Digital Glass Thickness Meter for Better Measurement

Time:2019/05/06 10:15:00 Browse:866

Insulating glass has better thermal insulation properties and also has the effect of reducing cold radiation. Whether it is a double or triple layer insulating glass, the thickness can be easily measured with the digital glass thickness meter LS201.

The optical properties of the insulating glass will have different characteristics depending on the choice of the original glass. How to measure glass thickness? Generally, the thickness of the insulating glass can be measured by a digital glass thickness meter LS201 which is digitally read. Customers can choose according to their needs.

digital glass thickness meter

LS201 Digital glass thickness meter

The insulating glass can improve the safety performance of the glass. In the case of using the original glass sheet of the same thickness, the wind-resistant strength of the insulating glass is 1.5 times that of the ordinary single-piece glass. The specific data reference analysis is as follows:

Since the desiccant capable of adsorbing water molecules exists inside the insulating glass, the gas is dry, so that the condensation does not occur inside the insulating glass when the temperature is lowered. At the same time, the dew point of the outer surface of the insulating glass will also rise. For example, when the outdoor wind speed is 5 m/s, the indoor temperature is 20 ° C, and the relative humidity is 60%, the 5 mm glass begins to dew at an outdoor temperature of 8 °C. The 16mm (5+6+5) insulating glass is exposed to condensation under the same conditions at an outdoor temperature of -2 °C, and 27 mm (5+6+5+6+5) three-layer insulating glass at outdoor temperature. condensation begins only at -11 °C.

The insulating performance of the insulating glass is good, so the temperature difference between the two sides of the glass is large, and the effect of reducing the cold radiation is also obtained. When the outdoor temperature is -10 ° C, the temperature in front of the indoor single-glazed window is -2 ° C, and the temperature in front of the insulating glass window is 13 ° C. In the same house structure, when the outdoor temperature is -8 ° C and the indoor temperature is 20 ° C, the ordinary single-layer glass cold radiation area of 3 mm accounts for 67.4% of the indoor space, while the double-layer insulating glass (3+6+3) is used. ) is 13.4%.

Whether it is 16mm (5+6+5) insulating glass or 27mm (5+6+5+6+5) three-layer insulating glass, it can be easily measured with the digital glass thickness meter LS201.

If you have any questions when using the digital glass thickness meter LS201 , you can consult the Linshang customer service Miss Yu 13826547799.

Enquiry

Enquiry


Click image refresh captcha
x