-
Window Detection Instrument- Visible Light Transmittance Meter
2019-07-09
Linshang LS110 visible light transmittance meter, professionally used to test the light transmittance of automotive windshield. This instrument can be used to detect the light transmission of the front, side and rear windshields of the car. The bright window action clearly specifies the light transm
-
Difference between Visible Light Transmission Meter LS183 and LS108H
2019-07-02
Both the LS183 and the LS108H visible light transmission meter are professionally used for optical transmission test of translucent materials such as foil, coating materials, organic materials, coatings, solar films, PMMA materials, and PC materials. Both meters can measure three parameters of UV, l
-
Densitometer Test Mobile Phone Cover Ink OD Value
2019-06-24
Linshang LS117 densitometer for sale has always been used to test the optical density of film, matte, milky white, fogged and other materials due to the unique diffuse transmission principle design. And it saves a lot of trouble for using integrating sphere to test. Linshang technology provides the
-
Portable Transmission Meter
2019-06-11
Among the series of Linshang solar film transmission meters, the products can be roughly divided into three types: small portable type, desktop display type, and split type. Different shapes have different application scenarios. For example, the portable one is especially suitable for carrying sampl
-
Light Transmittance of the Car Front Windshield Film
2019-06-06
A lot of car owners have recently reflected that after the front windshield film is applied, the sight line is blurred when passing through tunnels or rainy weather and night. This can easily lead to some traffic accidents, and some inferior membranes can even cause the front glass to burst. "What k
-
Ultra Clear Glass Advantages and VLT Measurement
2019-05-28
1. What is ultra clear glass? Ultra-white glass is a kind of ultra-transparent low-iron glass, also known as low-iron glass and high-transparent glass. It is a new type of high-quality, multi-functional high-end glass with a light transmittance of over 91.5%. It has the characteristics of crystal cl
-
Measurement of Optical Density
2019-05-10
Due to its characteristics, aluminized films have replaced aluminum foil composites in many respects .We can know the uniformity of the aluminized film by testing the optical density with Linshang LS 117 optical density meter. Aluminized film is a thin film of aluminum metal coated on the surface o
-
Transmission Meter for Lens and Phone Cover Test
2019-05-07
In the mobile phone cover industry, the LS108D mobile Lens transmission meter is used to test the transmittance of the distance and position sensing holes. The LS117 optical density meter is used to test the optical density of the screen printing ink, which perfectly solves the problem of the optica
-
Spectrum Transmission Meter for Measuring PC Sheet
2019-04-30
PC sheet has the advantages of good light transmission performance, light weight, good impact resistance, good sound insulation performance and good softness. Its light transmittance can also be measured by Spectrum transmittance meter LS108H. With the development of energy-saving and environmentall
-
How to test the transmittance of smart dimming glass?
2019-04-28
The dimming glass is designed in a modern and simple style, which perfectly reflects the modern and fashionable charm. The infrared transmission and ultraviolet transmission of the dimming glass can be measured by the LS183 smart dimming glass transmission meter, and the visible light transmittance
-
Spectacle lens anti-blue light detection---blue-violet light transmittance meter
2019-04-19
The blue light has a wavelength range of 400 nm to 480 nm and is a light with higher energy. Blue light in this wavelength increases the amount of toxins in the macular area of the eye, which is a serious threat to our eye health and can also cause eye disease. In fact, the really harmful blue light
-
Test Glassine Transmittance by Diffuse Transmission Material Transmittance Meter
2019-03-29
The sample received from the customer several days ago is a kinds of white thin paper that requires testing its transmittance. Consult the customer only to know that this kind of paper is called Glassine, the customer has got the date of 65% transmittance with an ordinary transmittance meter, but in
-
LS117 Optically Diffuse Materials Transmittance Meter
2019-03-29
LS117 Optical density meter can measure various of diffusive materials, such as milky, fogged, abrasive, matte and other translucent materials. “I bought the Window solar tester for the purpose of measuring the transmission of acrylic plates, however when I wanted to measure something that is optica
-
Difference between LS116 and LS117 Light Transmittance Meter
2019-03-29
Linshang has two light transmittance meters can be used to test the visible light transmittance. Actually there are not much difference between their appearance and parameters , but if the customer need to select a suitable instrument to test the light transmittance , firstly they need to know the m
-
Difference between LS117 Optical Density Meter and X-rite 341C
2019-03-29
Linshang LS117 optical density meter and X-rite 341C portable transmission densitometer can both test optical density and dot area, but these two instruments still have some difference. LS117 Optical Density Meter is used to measure the transmittance, optical density and dot area of the materials, w
-
The Definition of Optical Density and the Measurement
2019-03-29
Optical density is the natural logarithm of the ratio of incident to transmitted radiant power through a material. For measuring the optical density of some materials, you can use Linshang LS117 Optical Density Meter. What is the meaning of optical density? What is the meaning of optical density? H
-
Measuring the Transmittance of a Hemisphere by Plastic Transmittance Meter
2019-03-29
LS108H Plastic Transmittance Meter is mainly used to test organic materials, glass, PC material transmittance,the test aperture is 3mm,so it is more suitable for small size materials, can take simultaneously infrared and ultraviolet transmittance measurement. With a flat-panel design, it’s easy to p
-
Optical Density Meter Measure Aluminizer Thickness
2019-03-29
Due to the very thin thickness of aluminized layer on vacuum aluminizing film, therefore conventional thickness measurement instrument can't be used for the thickness detection.Optical density meter can be used to obtain the thickness uniformity of the tested materials. The principle of the optical
-
LS117 Optical Densitometer Measure Welding Mask Glass
2019-03-29
One customer from Taiwan called us asked if there is any suitable instrument recommend to test black glass. After a detailed understanding of the customer's sample, it’s black glass lens use on welding mask, about 3mm thickness, in the length and width is 108mm*50mm, they need to test the transmitta
-
LS117 Transmission Densitometer-Related Knowledge
2019-03-29
LS117 Transmission Densitometer is mainly used in: film, x-rays, a variety of aluminum, and opaque, foggy, scrub rough surfaces and other materials, for the absolute optical density, relative density and dot area rate measurement. Let’s show you more related knowledge about LS117 Transmission Densit
-
Difference of LS117 Densitometer and X-Rite 341 Densitometer
2019-03-29
After Linshang launched LS117 Densitometer, the instrument is very popular, Since American product X-Rite 341 is on market for long time, most of FAQs about LS117 is: what's the difference between with X-Rite 341. densitometer principle List below will show you details.1:Measure Scope LS117 Densito
-
LS117 Densitometer Measure Application
2019-03-29
LS117 densitometer is mainly used in: film, X-ray films, all kinds of aluminum foil, mist, frosted, rough surface and opalescent, ceramics, opaque silicone and rubber and other materials , to measure absolute optical density, relative optical density and dot area rate.The light source is under the i
-
Companre LS117 Optical Density Meter With Others
2019-03-29
After LS117 optical density meter been revised and upgraded in July 2014 ,it is favored by the major users. a lot of customers phone or online consulting related to the product's performance and knowledge, but FAQ are such as: what is the difference between X341 and integrating sphere photometer, cu
-
Difference of LS116 Transmission & LS117 OD Meter
2019-02-27
Recently, many customers asked aboutdifference of LS116 Transmission Meterand LS117 Optical Density Meter,customers thought that two types of instruments are for lighttransmittance ratio test, How todetermine which instrument is more suitable for testing their own products’material? In fact, this