Linshang Light Transmittance Meter

Time:2019/09/23 14:28:00 Browse:650

There are three main types of light transmittance in Linshang, they are LS110 split light transmittance meter, LS116 high-precision light transmittance meter, LS117 light transmittance meter (optical density meter). The design principles and characteristics of these three products are different. Below we will make a detailed introduction of the light transmittance meter.

Split light transmittance meter LS110

This product is mainly used for uniform and transparent automotive front windshield, architectural glass, and other installed glass. 

Parameter LS110 Split light transmittance meter
Light source 380nm-760nm full wavelength, in line with CIE photopic luminosity function
Accuracy better than ±2% (colorless uniform and transparent material)
Resolution 0.1% (0% --- 10%); 1% (10% --- 100%)
Sample diameter >40*40mm
Power supply Recharge Li-ion battery

LS110 light transmittance meter

Features of Split Light Transmittance MeterLS110:
     ● With three built-in visible light sources, the displayed transmittance results are the average of the three measured values, and the measurement results have strong anti-interference ability.
     ● With built-in rechargeable lithium battery for easier use.
     ● The laser alignment function is adopted to ensure the correct position and data accuracy of the main and auxiliary machines.
     ● With data lock function, easy to read after locking data

High-precision light transmittance meter LS116

This product is mainly used for the measurement of light transmittance of uniform and transparent glass, film glass and other materials. The use of parallel optical path design is also very suitable for detecting large thickness materials with an accuracy of ±1%. The light source complies with the CIE photopic luminosity function and ensures the detection by the metrology institute. 

Parameter LS116 high precision light transmittance meter
Light source 380nm-760nm full wavelength, in line with CIE photopic luminosity function
Accuracy better than ±1% (colorless uniform and transparent material)
Resolution 0.001% (0% --- 10%); 0.01% (10% --- 100%)
Sample diameter >10mm
Power supply 4*AAA alkaline dry battery

LS116 light transmittance meter

Features of High-precision light transmittance meter LS116:
● The instrument adopts parallel optical path design and can measure large thickness materials.
     ● The transmittance measurement range is 0.001%-99.8%, and the highest resolution is 0.001%. It can measure high transmittance materials.
     ● The instrument has two measurement methods, equipped with a special pedestal, the probe and receiver can be fixed on the pedestal for fixed-point testing, the light source and receiver can be also removed from it, the measurement method is more flexible.

Light transmittance meter LS117 (optical density meter)

Linshang LS117 densitometer is mainly used to measure the optical density and light transmittance of materials. It is suitable for the transmittance of diffuse transmission materials of various opalescent, foggy, frosted matte surfaces, and optical density measurement of X-ray film, aluminum film and various film. 

Parameter LS117 Transmittance Meter (Optical Densitometer)
Spectral range 380nm-760nm full wavelength, in line with CIE photopic luminosity function
Transmittance accuracy ±1% (0% --- 50%); ±2% (50% --- 100%)
Transmittance resolution 0.0005% (0% --- 10%); 0.005% (10% --- 100%)
OD measurement range 0.000 OD --- 6.000 OD
OD measurement accuracy ±0.02 (0 --- 2.00 OD); ±2% (2.00 --- 6.00 OD)
OD resolution 0.001 OD (0-2.0 OD); 0.01 OD (2.00 - 4.0 OD); 0.1 OD (4.0-6.0 OD)
Sample diameter >2mm
Power supply 4*AAA alkaline dry battery

Light Transmittance Meter LS117

Features of Light Transmittance Meter LS117 (Optical Densitometer):
● The instrument adopts the principle of diffuse transmission, which can meet the requirements of transparent and translucent transmittance test.
     ● With two measurement methods, equipped with a special pedestal, the probe and receiver can be fixed on the pedestal for fixed-point testing, the light source and receiver can be also removed from it, the measurement method is more flexible.
     ● With high precision, wide measurement range, optical density value can be measured up to OD6.
     ● The transmittance and optical density can be measured simultaneously.
       For more information about light transmittance meter, please refer to https://www.linshangtech.com/tech/tech559.html